QUESTION 1.3.2
Are combustible materials and waste stored away from sources of ignition?
Clear the waste and stored items from beside the electrical intake cupboard and agree a collection schedule with the managing agent. Re-inspect within 7 days.
⚖ RRO 2005, Art. 9Marked compliant — no remedial action required.
QUESTION 1.2.1
Has the fixed electrical installation been inspected and tested within the recommended interval?
Arrange an Electrical Installation Condition Report by a competent electrician and remedy any C1 or C2 observations. Record the next due date.
⚖ RRO 2005, Art. 9 • BS 7671Marked compliant — no remedial action required.
QUESTION 2.4.1
Are escape routes kept clear of combustible materials and obstructions?
Remove stored items from the protected stairwell and implement a documented ‘clear corridor’ policy. Re-inspect within 7 days and record completion.
⚖ RRO 2005, Art. 14 • BS 9999Marked compliant — no remedial action required.
QUESTION 2.4.2
Are fire doors fitted with effective self-closing devices?
Adjust or replace the self-closing devices so each door closes fully onto its latch from any angle, and include these doors in the routine fire door checks.
⚖ Fire Safety (England) Regs 2022 • BS 8214Marked compliant — no remedial action required.
QUESTION 3.1.2
Is the fire alarm tested weekly from a different call point, and the test recorded?
Introduce a weekly fire alarm test, using a different call point each week, and record each test in the fire log book.
⚖ RRO 2005, Art. 17 • BS 5839-1Marked compliant — no remedial action required.
QUESTION 3.2.1
Have staff received fire safety training, repeated periodically?
Provide fire safety training for all staff on induction, repeat it periodically, and keep a record of who attended.
⚖ RRO 2005, Art. 21Marked compliant — no remedial action required.
QUESTION 4.1.1
Is there a secure information box holding the building’s floor plans and responsible person’s details?
Install a secure information box accessible to the fire and rescue service, containing the floor plans, single-page building plan and the responsible person’s contact details.
⚖ Fire Safety (England) Regs 2022Marked compliant — no remedial action required.
QUESTION 4.2.1
Is wayfinding signage visible in low light or smoky conditions on every floor?
Fit floor identification and flat indication signs in each stair and lobby, visible in low light or smoky conditions.
⚖ Fire Safety (England) Regs 2022Marked compliant — no remedial action required.
FD-014 · FLAT 12 ENTRANCE · FD30S
4.3 Lock-side gap within tolerance (typically 3mm ±1mm)
Reading 7 mm. Leaf binding on the frame at the latch. Recommended action: Repair. Added to the door action plan.
Reading 3 mm, within tolerance.
5 · SEALS
5.1 Intumescent strips present, continuous and undamaged
The problem
Fire safety compliance is high-stakes, and most tooling fights you.
Word docs & spreadsheets
Inconsistent templates, door registers in Excel, photos called IMG_4471, and findings that are easy to miss or mis-number.
Action plans from memory
Recommending remedial actions and citing the right regulation by hand is slow and error-prone.
Shifting legislation
The Building Safety Act and 2022 Regulations changed what’s required — especially for high-rise buildings.
Reports take hours
Formatting a credible, branded report after every site visit eats into billable time.
Two products, one place
Everything you inspect, on one platform.
Use either on its own or both together, on one subscription and one invoice. Add or switch off a product whenever you like.
Fire risk assessments
A guided question set following PAS 79, AI action plans citing the legislation, Building Safety Act awareness and a branded PDF report.
Pay as you go from £12 an assessment, or subscribe from £95 a month
Explore fire risk assessments →Fire door inspections New
Import the door register, work through a 46-point checklist on your phone, and issue a report with a door action plan and compliance matrix.
£1 a door, charged when you issue the report. No monthly fee
Explore fire door inspections →Clients and buildings
Never miss a review.
Keep your clients and their buildings in one place, and see at a glance when each one is next due: its fire risk assessment review, and its next fire door inspection.
- ✓ Review dates worked out from the last assessment and the building's cycle
- ✓ Fire door inspections due from the last report and how often the client has them done
- ✓ Overdue and due in the next 60 days, flagged across every client
How it works
From site visit to signed-off report, whatever you’re inspecting.
Inspect on site
Work through a fire risk assessment’s guided questions, or a building’s fire doors door by door, on a phone, tablet or laptop. Photos go in as you go, even where the signal drops.
Action plan
Every FRA non-compliance gets a prioritised, cited remedial action drafted for you. Every failed door lands in the door action plan, most urgent first.
Report
Issue a branded, audit-ready PDF with your logo, ready to share with the responsible person and keep on file.
Never miss the next one
Your Clients page shows when each building is next due, for its FRA review and its fire doors.
Coming soonTrack every action through to completion.
Frequently asked questions
Does Assura Safety guarantee compliance?+
No software can guarantee compliance. Assura Safety helps you carry out, document and report a fire risk assessment against UK legislation and standards — the professional judgement, and responsibility, remain with the competent assessor and the responsible person.
How do the AI action plans work?+
When you record a non-compliance, the app drafts a prioritised remedial action grounded in a tagged library of UK fire legislation and standards, citing the specific regulation or standard. Every action is fully editable — you control the wording, priority, timescale and assignee.
What does a fire door inspection in Assura cover?+
Each door is checked against 46 points in 12 sections: certification and identification, the door leaf, frame, gaps, intumescent and smoke seals, hinges, the self-closing device, latch and ironmongery, glazing, hold-open devices, signage and how the door is used. Checks that don't apply to a door, such as glazing on a solid door, are left out automatically. You record gap readings, photos and a priority for each defect, and a recommended action for the door as a whole.
How much do fire door inspections cost?+
£1 per door plus VAT, charged when you issue the report. There's no monthly fee. If you reopen a report and issue it again, you're only charged for doors added since. You give a card when you sign up, and nothing is charged until you issue your first report.